#vitalstream_caretaker_メディカルテクニカ
Medical Teknika リンク集 #VitalStream
メディカルテクニカ有限会社
!doctype>
2023年12月29日金曜日
Aortic Pulse Wave Velocity Measured by Occlusive, Suprasystolic, Oscillometric Method (Arteriograph) Independently Predicts all Cause Mortality
Artery Research
Volume 25, Issue Supplement 1, December 2019, Pages S32 - S32
4.3 Aortic Pulse Wave Velocity Measured by Occlusive, Suprasystolic,
Oscillometric Method (Arteriograph) Independently Predicts all Cause Mortality
Authors
Miklos Illyes*
Heart Institute, Faculty of Medicine, University of Pécs, Pécs Hungary
Available Online 15 February 2020.
DOI
10.2991/artres.k.191224.024How to use a DOI?
Abstract
Introduction: It has been long debated whether Arteriograph predicts cardiovascular events
and/or all cause mortality, despite that its prognostic value has been proven
in systolic heart failure and in myocardial infarction already. However,
no data were available about the prognostic value of this method in general population.
Materials and Methods: Altogether 4146 subjects in the age range of 35–75 years
(mean age 53.2 ± 9.2 years, male/female 2042/2104, SBP/DBP 136.5/82.1 ± 20.1/11.3 mmHg,
treated hypertension 47.6%, treated diabetes 8.5%, total se-cholesterol 5.2 mmol/l)
were measured in multiple centers in Hungary. Subjects visited
the outpatient centers on their own initiative. Information on registered hospitalization events,
mortality and medical treatment was provided by the Hungarian National Health Insurance Fund (HNHIF).
For privacy protection reasons the data were managed and analyzed by the HNHIF.
The PWVao measurements were performed by an invasively validated occlusive, suprasystolic,
oscillometric method (Arteriograph).
Results: The mean follow-up was 5.5 years. 116 all-cause mortality events were observed.
By univariate analysis 1 m/s increase in PWVao resulted HR 1.71 (1.47–1.98; 95% CI).
In multivariate Cox analysis Aortic PWV independently predicted (p = 0.002)
the all-cause mortality in the final model of multivariate analysis (1.34 [1.12–1.62])
adjusted for age, gender, mean arterial pressure, pulse pressure, ejection duration
and antiplatelet drug treatment. Body mass index, smoking, heart rate, blood pressure,
augmentation index, diabetes, and cardiovascular drug therapy were all accounted for.
Conclusion: The PWVao, measured by an easy-of-use, user independent, oscillometric method
in a large population, proved to be a strong, independent predictor of all-cause mortality.
登録:
コメントの投稿 (Atom)
#VitalStream_caretaker_メディカルテクニカ
#VitalStream_caretaker_メディカルテクニカ
-
wavelet 原理の生体情報解析が、いよいよ、突然死・sudden_death の分野で真価が問われる時代に入った、メディカルテクニカはこの分野の技術を創業時からご案内してきた
0 件のコメント:
コメントを投稿